{"compilation": {"title": "Solubility data from IUPAC SDS Volume 37 (page 30) - 2,2-Dimethylpropane with Water", "publisher": "The International Union of Pure and Applied Chemistry", "keywords": "Solubility, Solubility data series", "compilers": "Z. Maczynska, Andrzej Maczynski, A. Szafranski", "sources": [{"citation": "McAuliffe, C.; J. Phys. Chem. 1966, 70, 1267-1275.", "pubtype": "paper", "url": "https://doi.org/10.1021/j100876a049"}], "system": "2,2-Dimethylpropane with Water", "substances": [{"constituent": 1, "name": "2,2-Dimethylpropane", "formula": "C5H12", "molweight": 72.1488, "casrn": "463-82-1", "inchi": "InChI=1S/C5H12/c1-5(2,3)4/h1-4H3", "inchikey": "CRSOQBOWXPBRES-UHFFFAOYSA-N", "sample": "Phillips Petroleum or Columbia Chemical; used as received."}, {"constituent": 2, "name": "Water", "formula": "H2O", "molweight": 18.0153, "casrn": "7732-18-5", "inchi": "InChI=1S/H2O/h1H2", "inchikey": "XLYOFNOQVPJJNP-UHFFFAOYSA-N", "sample": "Distilled."}], "method": "In a 250 mL glass bottle, 10-20 mL of (1) was vigorously shaken for 1 hr or magnetically stirred for 1 day, with 200 mL of (2) at 25 \u00b0C. In the case of shaking, the solution was allowed to stand for 2 days to permit separation of small (1) droplets. Absence of emulsion was checked microscopically. A sample of the hydrocarbon-saturated water was withdrawn with a Hamilton syringe and gas liquid chromatographed in conjunction with a flame-ionization detector.", "dataset": []}}