{"compilation": {"title": "Solubility data from IUPAC SDS Volume 38 (page ?) - Styrene with Water", "publisher": "The International Union of Pure and Applied Chemistry", "keywords": "Solubility, Solubility data series", "compilers": "Z. Maczynska, Andrzej Maczynski", "sources": [{"citation": "Andrews, L. J.; Keefer, R. M.; J. Am. Chem. Soc. 1950, 72, 5034-7.", "pubtype": "paper", "url": "https://doi.org/10.1021/ja01167a058"}], "system": "Styrene with Water", "substances": [{"constituent": 1, "name": "Styrene", "formula": "C8H8", "molweight": 104.149, "casrn": "100-42-5", "inchi": "InChI=1S/C8H8/c1-2-8-6-4-3-5-7-8/h2-7H,1H2", "inchikey": "PPBRXRYQALVLMV-UHFFFAOYSA-N", "sample": "Eastman Kodak Co., white label; distilled shortly before use; 1 wt% of hydroquinone added as stabilizer before distillation; b.p. 76 C (78 mm Hg)."}, {"constituent": 2, "name": "Water", "formula": "H2O", "molweight": 18.0153, "casrn": "7732-18-5", "inchi": "InChI=1S/H2O/h1H2", "inchikey": "XLYOFNOQVPJJNP-UHFFFAOYSA-N", "sample": "not specified."}], "method": "A mixture of (1) and (2) was rotated for twethy hours in a constant temperature bath as 25\u00b0C. A sample (5-20 mL) of the aqueous phase was withdrawn and extracted with a measured volume of hexane (10-50 mL) by shaking in a glass-stoppered Erlenmeyer flask. Next, the absorbance of the hexane phase was measured against a hexane blank on the Beckman spectrophotometer.", "dataset": []}}