Components:
(1) Fluorobenzene,
C6H5F; [462-06-6]
NIST WebBook
(2) Water,
H2O; [7732-18-5]
NIST WebBook
Original Measurements
Andrews, L. J.; Keefer, R. M.; J. Am. Chem. Soc. 1950, 72(7), 3113-6.
Variables:
Ambient temperature: One temperature
Prepared by:
Method/Apparatus/Procedure:
The water was saturated with fluorobenzenein a glass-stoppered Erlenmeyer flask rotated in a constant temperature bath for 20 hours. The saturated solution was extracted with n-hexane. The optical density of the extract was measured against a standard n-hexane blank with a Beckman spectrophotometer (1).
Source and Purity of Materials:
- Eastman Kodak Co., commercial reagent, b.p 84.4°C, fractionated before use.
- not specified.
Estimated Errors:
Ambient temperature: ±0.1 K (compiler).
Mass concentration (m/v) (1): ±10% (compiler).
References
1 Andrews, L. J.; Keefer, R. M.; J. Am. Chem. Soc. 1949, 71, 3644-77.
Experimental Values:
| T (°C) | x1 | C1 (mol/dm3) |
|---|---|---|
| 25.0 | 2.918 x 10-4 | 1.613 x 10-2 |
(a) Reported. (b) Calculated by F. W. Getzen. (c) Calculated by the compiler.